抗干擾 異變頻介質損耗測試儀

產品名稱:抗(kang)干擾 異變頻介(jie)質損(sun)耗測試儀

產品型號:

產品報價:

產品特點:抗干(gan)擾 異變頻介質損耗測試(shi)儀具備輸入(ru)電(dian)壓波動、高(gao)壓電(dian)流、輸出短路、電(dian)源故(gu)障、過(guo)壓、過(guo)流、溫度等多重保護措施,保證了儀器安全、可靠。儀器還(huan)具備設置接(jie)地檢(jian)測功(gong)能,確(que)保不(bu)接(jie)地設備不(bu)允許升(sheng)壓。

抗干擾 異變頻介質損耗測試儀的詳細資料:

一、抗干擾 異變頻介質損耗測試儀產品概述

是發電(dian)廠、變(bian)電(dian)站(zhan)等現場或(huo)實(shi)驗室測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)各(ge)種高壓(ya)(ya)電(dian)力設(she)備介(jie)損(sun)正(zheng)切值及電(dian)容量的(de)(de)高精度測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)儀(yi)器(qi)(qi)(qi)。儀(yi)器(qi)(qi)(qi)介(jie)質損(sun)耗(hao)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)儀(yi)為(wei)一體化結構,內(nei)置(zhi)介(jie)損(sun)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)電(dian)橋,可變(bian)頻調壓(ya)(ya)電(dian)源,升(sheng)壓(ya)(ya)變(bian)壓(ya)(ya)器(qi)(qi)(qi)和(he)SF6高穩定度標準(zhun)電(dian)容器(qi)(qi)(qi)。測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)高壓(ya)(ya)源由儀(yi)器(qi)(qi)(qi)內(nei)部的(de)(de)逆變(bian)器(qi)(qi)(qi)產生,經變(bian)壓(ya)(ya)器(qi)(qi)(qi)升(sheng)壓(ya)(ya)后(hou)(hou)用(yong)于被試(shi)(shi)品(pin)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)。頻率(lv)可變(bian)為(wei)50Hz、47.5Hz52.5Hz、45Hz55Hz、60Hz、57.5Hz62.5Hz、55Hz65Hz,采用(yong)數字陷波技(ji)術,避開(kai)了工(gong)頻電(dian)場對(dui)測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)的(de)(de)干(gan)(gan)擾,從(cong)根本上解決了強電(dian)場干(gan)(gan)擾下準(zhun)確測(ce)(ce)(ce)(ce)(ce)量的(de)(de)難(nan)題。同時適用(yong)于全部停(ting)電(dian)后(hou)(hou)用(yong)發電(dian)機供電(dian)檢測(ce)(ce)(ce)(ce)(ce)的(de)(de)場合。該儀(yi)器(qi)(qi)(qi)配以絕緣油(you)杯加溫控裝置(zhi)可測(ce)(ce)(ce)(ce)(ce)試(shi)(shi)絕緣油(you)介(jie)質損(sun)耗(hao)。

儀器主要具(ju)有如下特點:

l 科學*的(de)數據管理

儀器數據(ju)可以通過U盤導出,可在(zai)任意(yi)一臺PC機上通過我公(gong)司(si)軟件,查看和管理數據(ju)

l 異頻介質損耗測試儀多種測試模式

儀器使用(yong)內高壓、內標準的(de)方式測試(shi),正接(jie)法(fa)、反接(jie)法(fa)、自激(ji)法(fa).

l CVT測試一步(bu)到(dao)位

該儀器還可以測試全密封的CVT(電容式電壓互感(gan)器)C1、C2的介(jie)損和(he)電容量。


l 不拆高壓(ya)引(yin)線測量CVT

儀器可在(zai)不拆除(chu)CVT高壓引線的情況下(xia)正確(que)測(ce)量CVT的介質損(sun)耗(hao)值(zhi)和電容值(zhi)。

l CVT反接屏蔽法測量C0

儀器可采用反(fan)接屏蔽法測(ce)量CVT上端C0的介(jie)質損耗值和電容值。

l 高速采樣信號

儀(yi)器內(nei)部(bu)的逆變器和(he)采(cai)樣電路全(quan)部(bu)由數字化控制,輸出電壓連(lian)續可調。

l 多重保(bao)護安全可(ke)靠

儀器(qi)具備(bei)輸入電(dian)壓(ya)波(bo)動、高壓(ya)電(dian)流(liu)、輸出短路、電(dian)源故障、過壓(ya)、過流(liu)、溫度等多重保護(hu)措(cuo)施,保證了儀器(qi)安(an)全(quan)、可靠。儀器(qi)還具備(bei)設置接(jie)地檢測功能,確保不(bu)接(jie)地設備(bei)不(bu)允許(xu)升壓(ya)。

二、工作原理

在(zai)交流電(dian)(dian)(dian)(dian)壓作(zuo)用下,電(dian)(dian)(dian)(dian)介(jie)質(zhi)(zhi)要消耗部(bu)分電(dian)(dian)(dian)(dian)能(neng)(neng),這部(bu)分電(dian)(dian)(dian)(dian)能(neng)(neng)將(jiang)轉變為(wei)熱能(neng)(neng)產(chan)生(sheng)損(sun)(sun)耗。這種能(neng)(neng)量(liang)損(sun)(sun)耗叫做電(dian)(dian)(dian)(dian)介(jie)質(zhi)(zhi)的(de)損(sun)(sun)耗。當電(dian)(dian)(dian)(dian)介(jie)質(zhi)(zhi)上施加交流電(dian)(dian)(dian)(dian)壓時,電(dian)(dian)(dian)(dian)介(jie)質(zhi)(zhi)中(zhong)的(de)電(dian)(dian)(dian)(dian)壓和電(dian)(dian)(dian)(dian)流間成(cheng)在(zai)相(xiang)角差ψ,ψ的(de)余(yu)角δ稱為(wei)介(jie)質(zhi)(zhi)損(sun)(sun)耗角,δ的(de)正切(qie)(qie)tgδ稱為(wei)介(jie)質(zhi)(zhi)損(sun)(sun)耗角正切(qie)(qie)。tgδ值(zhi)(zhi)是用來衡量(liang)電(dian)(dian)(dian)(dian)介(jie)質(zhi)(zhi)損(sun)(sun)耗的(de)參數。儀(yi)器(qi)測(ce)量(liang)線(xian)路包(bao)括(kuo)一標(biao)準(zhun)回路(Cn)和一被(bei)試(shi)回路(Cx),如圖2—1所(suo)示。標(biao)準(zhun)回路由(you)(you)內置高穩定(ding)度標(biao)準(zhun)電(dian)(dian)(dian)(dian)容器(qi)與測(ce)量(liang)線(xian)路組(zu)成(cheng),被(bei)試(shi)回路由(you)(you)被(bei)試(shi)品和測(ce)量(liang)線(xian)路組(zu)成(cheng)。測(ce)量(liang)線(xian)路由(you)(you)取樣電(dian)(dian)(dian)(dian)阻(zu)與前置放大器(qi)和A/D轉換器(qi)組(zu)成(cheng)。通過(guo)測(ce)量(liang)電(dian)(dian)(dian)(dian)路分別(bie)測(ce)得(de)(de)標(biao)準(zhun)回路電(dian)(dian)(dian)(dian)流與被(bei)試(shi)回路電(dian)(dian)(dian)(dian)流幅值(zhi)(zhi)及其相(xiang)位(wei)差,再由(you)(you)數字信號處理器(qi)運用數字化實(shi)時采集方法,通過(guo)矢(shi)量(liang)運算得(de)(de)出試(shi)品的(de)電(dian)(dian)(dian)(dian)容值(zhi)(zhi)和介(jie)質(zhi)(zhi)損(sun)(sun)耗正切(qie)(qie)值(zhi)(zhi)。

安全措施:

1、 使用(yong)本(ben)儀(yi)器前一定(ding)要認(ren)真(zhen)閱(yue)讀本(ben)手冊。

2、操作者應具備一(yi)般電(dian)氣設備或儀器的使用常(chang)識。

3、儀器應避免(mian)劇烈振動。

4、儀器必須可靠接地,防止觸(chu)電危險(xian)。

5、測(ce)試結束(shu)后,按復(fu)位鍵(jian),關(guan)掉電(dian)源開關(guan),嚴禁(jin)帶電(dian)拆裝各測(ce)試電(dian)纜和更換油樣。

使用條(tiao)件 -15℃~40℃;RH<80%

電 源 AC 220V±10%,頻率無限制
交流高壓輸出 400V~2200V ±2% ,每隔100V 50VA
直流高壓輸出 200V~600V ±2%,每隔50V
溫控感應爐 zui大功率500W
溫度控制范圍<100℃
溫度控制誤差 ±0.5℃
溫度測量分辨率 0.1℃
控溫(wen)時間 室溫(wen)到(dao)90℃, 小于20min

三、抗(kang)干擾(rao) 異變頻(pin)介質損耗測(ce)試儀注意事項
1、遵守本單位的高壓試驗安全工作規程。
2、高壓試驗必須(xu)由2名(ming)以(yi)上工(gong)作人員參加(jia),1人操(cao)作,1人監護。
3、接線完畢后,由(you)1人負責檢查。
4、測(ce)試結束后,關(guan)閉電(dian)源開(kai)關(guan)。嚴禁帶電(dian)拆(chai)裝高壓(ya)電(dian)纜!
5、儀(yi)器出現不(bu)正常現象,關閉(bi)電源(yuan)開關,等待一分鐘左(zuo)右再檢查。
6、反接線(xian)校(xiao)驗(yan)標準介損器時,將標準介損器放(fang)在絕緣物體上(shang),離地60-100cm,將高壓電纜接頭懸空吊(diao)起遠離地面,避免高壓線(xian)夾對地的分布(bu)參數(shu)影響數(shu)據。
7、高(gao)壓(ya)電纜損壞時,可以用(yong)低壓(ya)CX線懸空使用(yong),本產(chan)品高(gao)低壓(ya)電纜接(jie)線方式相同,可以互換使用(yong)。。
8、測量完畢必須(xu)關閉(bi)電源(yuan)開關,等待一分(fen)鐘左右再(zai)拆線。

更多產品選型請來揚州豪泰電力科技有限公司,產品變頻介質損耗測試儀售后無憂,歡迎你前來選購。


 如果你對抗干擾 異變頻介質損耗測試儀感興趣,想了解更詳細的產品信息,填寫下表直接與廠家聯系:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算(suan)結(jie)果(guo)(填寫阿拉伯數字),如:三加四=7
網站首頁 - 關于我們 - 產品中心 - 新聞資訊 - 技術文章 - 聯系方式 -
Copyright © 2013 揚州豪泰電力科技有限公司 版權所有    
公司地址:揚州寶應柳堡工業園區68號     GoogleSitemap
揚州豪泰電力科技有限公司專業提供抗干擾 異變頻介質損耗測試儀產品信息,歡迎來電咨詢!